Descriere

Function description


 1. Automatic Charge control function:


 By setting the volt-HI:‘UP’ volt-LI:‘dn’;When the battery voltage is below the volt-LI:’dn’,the relay leads,the charger begins to charge the battery;when the battery voltage is up to volt-HI:’UP’,the relay is diconnected and the automatic charge is completed once;


 2. Charge Time Control Function:


 How to turn on the time control function?


 After entering the parameter set, set the parameter op is non-zero, then turn on the time control function, op default parameter is:--:--h, the default does not turn on time control function;


After the opening Time control function (OP is non-zero), when the battery voltage is the lower volt-LI’dn’, the charger began to charge the battery, the system began to clock; During the timing, the battery voltage ≥ volt-HI’UP’, relay disconnect; If the OP time is up, the battery voltage is still the lower volt-LI’dn’, the relay keeps the conduction, automatically closes the charge time control function, and flashes the H:ER to remind the user, the time parameter setting is unreasonable; Press any key to stop flashing;


Note: Time format: 00:59 (00 for hours, 59 for minutes) The maximum time is 99:59, which is 100 hours.


 XY-L30A Lithium Lead-Acid Battery Charge charging Control Module 6-60V 30A Timer Overcharge Protection Relay board


  


3. Serial data upload and parameter setting function:


  


The system supports UART data upload and parameter setting


UART:115200,8,1


 Data Upload message Format:


Battery voltage + battery percent + charge time + charge status 12.0V,020%,00:10,OP


 XY-L30A Lithium Lead-Acid Battery Charge charging Control Module 6-60V 30A Timer Overcharge Protection Relay board


 4.Parameter Setting


 a) Press and hold the SET key to enter the setting interface;


b) Switch the parameters you want to set by short press SET;


c) After the selection of parameters, can be set by the UP/DOWN key to support the short press, long press (fast increase or decrease); To set other parameters, repeat step b, c);


d) After all parameters are set, long press set key to exit and save;


  


5 Key Function Description:


 In the Run interface (main interface):


Short press SET button to display the current set of parameters; Short press UP button, toggle display charge percentage and charging time;


Short Press DOWN button, select Turn on/off relay enabling, if the relay can be closed, will show ' off ' as a reminder;


Long press UP button, switch low power state


on:No operation in 10 minutes turn off backlight


OFF: Backlight is always bright


Long press SET button,enter the parameter settings.


  


Calculation of voltage percentage:


voltage percentage = battery voltage/(volt-HI – volt-LI)


6.Additional Features


a) Charging time recording function: not open charging time control, the product will record a full time, when the entry time display interface, flashing display charging time, and then exit time display interface or next charge to open (relay conduction) when empty;


b) Automatic parameter detection: When the parameters are set, exit, if volt-LI dn≥ volt-HI UP, the system will flash display "ERR" as a reminder;


c) Battery Access detection: This product attached to the battery, if not connected to the battery, the system will be shown in the downlink "NbE" as a reminder